Accendo Reliability

Your Reliability Engineering Professional Development Site

  • Home
  • About
    • Contributors
    • About Us
    • Colophon
    • Survey
  • Reliability.fm
  • Articles
    • CRE Preparation Notes
    • NoMTBF
    • on Leadership & Career
      • Advanced Engineering Culture
      • ASQR&R
      • Engineering Leadership
      • Managing in the 2000s
      • Product Development and Process Improvement
    • on Maintenance Reliability
      • Aasan Asset Management
      • AI & Predictive Maintenance
      • Asset Management in the Mining Industry
      • CMMS and Maintenance Management
      • CMMS and Reliability
      • Conscious Asset
      • EAM & CMMS
      • Everyday RCM
      • History of Maintenance Management
      • Life Cycle Asset Management
      • Maintenance and Reliability
      • Maintenance Management
      • Plant Maintenance
      • Process Plant Reliability Engineering
      • RCM Blitz®
      • ReliabilityXperience
      • Rob’s Reliability Project
      • The Intelligent Transformer Blog
      • The People Side of Maintenance
      • The Reliability Mindset
    • on Product Reliability
      • Accelerated Reliability
      • Achieving the Benefits of Reliability
      • Apex Ridge
      • Field Reliability Data Analysis
      • Metals Engineering and Product Reliability
      • Musings on Reliability and Maintenance Topics
      • Product Validation
      • Reliability by Design
      • Reliability Competence
      • Reliability Engineering Insights
      • Reliability in Emerging Technology
      • Reliability Knowledge
    • on Risk & Safety
      • CERM® Risk Insights
      • Equipment Risk and Reliability in Downhole Applications
      • Operational Risk Process Safety
    • on Systems Thinking
      • Communicating with FINESSE
      • The RCA
    • on Tools & Techniques
      • Big Data & Analytics
      • Experimental Design for NPD
      • Innovative Thinking in Reliability and Durability
      • Inside and Beyond HALT
      • Inside FMEA
      • Institute of Quality & Reliability
      • Integral Concepts
      • Learning from Failures
      • Progress in Field Reliability?
      • R for Engineering
      • Reliability Engineering Using Python
      • Reliability Reflections
      • Statistical Methods for Failure-Time Data
      • Testing 1 2 3
      • The Manufacturing Academy
  • eBooks
  • Resources
    • Accendo Authors
    • FMEA Resources
    • Glossary
    • Feed Forward Publications
    • Openings
    • Books
    • Webinar Sources
    • Podcasts
  • Courses
    • Your Courses
    • Live Courses
      • Introduction to Reliability Engineering & Accelerated Testings Course Landing Page
      • Advanced Accelerated Testing Course Landing Page
    • Integral Concepts Courses
      • Reliability Analysis Methods Course Landing Page
      • Applied Reliability Analysis Course Landing Page
      • Statistics, Hypothesis Testing, & Regression Modeling Course Landing Page
      • Measurement System Assessment Course Landing Page
      • SPC & Process Capability Course Landing Page
      • Design of Experiments Course Landing Page
    • The Manufacturing Academy Courses
      • An Introduction to Reliability Engineering
      • Reliability Engineering Statistics
      • An Introduction to Quality Engineering
      • Quality Engineering Statistics
      • FMEA in Practice
      • Process Capability Analysis course
      • Root Cause Analysis and the 8D Corrective Action Process course
      • Return on Investment online course
    • Industrial Metallurgist Courses
    • FMEA courses Powered by The Luminous Group
    • Foundations of RCM online course
    • Reliability Engineering for Heavy Industry
    • How to be an Online Student
    • Quondam Courses
  • Calendar
    • Call for Papers Listing
    • Upcoming Webinars
    • Webinar Calendar
  • Login
    • Member Home
  • Barringer Process Reliability Introduction Course Landing Page
  • Upcoming Live Events
You are here: Home / Articles / Experiences with Magnetic Drive Pumps

by Mike Sondalini 3 Comments

Experiences with Magnetic Drive Pumps

Experiences with Magnetic Drive Pumps

Experiences with magnetic (magdrive) pumps. Magnetic drive pumps come in three varieties – canned motor pumps, all metal pumps and plastic lined metal pumps. They are sealless and cannot leak into the environment. Long, repair- free service life depends on recognising the limitations of these pumps. This article covers issues with using direct mounted, lined magdrive pumps experienced ‘in the field’.

Keyword: separation liners, chemical compatibility, sediment, particulate. 

The smaller magdrive pumps sizes come with motors direct mounted to the pump and there are no shaft alignment problems. The internal bearings and shaft in the plastic lined pumps are usually corrosion-free hard silicon carbide. The process liquid lubricates the bearing surfaces. Canned motor pumps have dual containment.

Figure 1 Simplified cross-section of a magdrive pump.
Figure 1 Simplified cross-section of a magdrive pump.

They operate by using magnetic attraction and repulsion to turn the impeller. Within the pump is a set of high strength permanent magnets imbedded around the outside of a hub projecting from the back of the impeller. A thin liner or shroud with a small (2 – 4 mm) clearance to the hub seals the pump internals. At a similar distance on the outside of the liner is another set of magnets connected to the motor. As the motor turns the outside magnets drive the inside magnets.

Here are some problems that can arise with magdrive pumps.

  • They cannot be run dry for more than a few seconds. When the bearings loose lubrication heat is quickly generated and conducted through the bearings. Plastic impellers can distort. Install no flow detection, like a flow switch or under-current detection, to protect the pump.
  • A high amount of heat can be generated by the coupling action of the magnets. This is worst in the canned motor and metallic pumps. The heat warms the liquid in the pump and is passed into the process. In a refrigeration system the excess heat may exceed the design loads for the system.
  • The pumps do not tolerate particulate and sediment in the pumped fluid. Because the process fluid lubricates the bearings, entrained sediment can block galleys and ports supplying lubrication. Only use them on clean fluids.
  • Sediment will also work its way into the thin cavity between the outside of the impeller hub and the inside of the separation liner. The sediment is dragged around by the impeller hub and scours the liner. If allowed to continue the sediment gouges through the separation shroud and the pump leaks.
  • Sediment settling on the bottom of tanks may come lose and be drawn through the pump. Set pump suction nozzles well off the tank floor.
  • The heat generated by the action of the magnets may be high enough to bake constituents of the process liquid onto the impeller magnet hub and a build-up develops.
  • Processes involving liquids that crystallise at room temperatures, or higher, require the pump to be trace heated to prevent crystals forming in internal cavities.
  • Internal plastic liners of magdrive pumps are susceptible to damage if hard foreign objects are drawn through the pump. Install a suction strainer if the process can contain large foreign materials like wood and rock. Large solids can also block impeller passages.
  • Separation liners made of non-conducting materials such as fiberglass and plastic composites cannot handle high pressure. If the pump experiences hydrostatic pressure from thermal expansion of liquid trapped between valves, or pressure hammers from fast closing valves, it is likely the separation liner will crack or rupture. Relieve thermal pressure build-up if closed valves can isolate the pump.
  • Ferrous particles, such as rust or steel filings, will be attracted to the magnets. It is a particular problem when bulk solids containing traces of ferrous metal are dissolved in a tank or where tank bottoms are being cleaned out. In-line magnets on the pump suction can help reduce the problem, or the tank contents can be let to settle and then the clear liquid above pumped out. The contaminated ullage is handled separately by a different style of pump or method.
  • Keep fingers away from the back of the impeller when it is reinstalled. The magnetic attraction between the inner and outer magnets cannot be restrained by hand and people have been hospitalised with crushed fingers.
  • Under high unexpected flows and pressures the pump is required to deliver more power through the impeller. If the conditions are beyond the capacity of the pump, the magnets de-couple and the drive is lost. To reengage the magnets the pump needs to be stopped and restarted. When selecting a magdrive pump chose one that will handle likely peak conditions.
  • In some situations the chemical being pumped has diffused through the plastic lining and attacked the underlying metal. This occurred on a magdrive pump pumping 26% HCl at 80o C. Through a manufacturing error the plastic lining over the impeller magnets was not up to standard and the HCl diffused through to the magnets where is corroded them and caused the inner magnet hub to bulge and rub against the separation shroud. Eventually the impeller jammed and would not turn.
  • If you don’t need the liner for chemical protection then you can get a cheaper all-metal pump.
  • These pumps can be wired-up incorrectly and run backwards. They will seem as if they are pumping but the flows and pressures will be much less then if they were going the right way.

Mike Sondalini – Maintenance Engineer

[ninja_form id=431]

Filed Under: Articles, on Maintenance Reliability, Plant Maintenance Tagged With: Pumps

About Mike Sondalini

In engineering and maintenance since 1974, Mike’s career extends across original equipment manufacturing, beverage processing and packaging, steel fabrication, chemical processing and manufacturing, quality management, project management, enterprise asset management, plant and equipment maintenance, and maintenance training. His specialty is helping companies build highly effective operational risk management processes, develop enterprise asset management systems for ultra-high reliable assets, and instil the precision maintenance skills needed for world class equipment reliability.

« Risk Decisions and Human Nature
Quantify Your Improvements with Maintenance Planning & Scheduling »

Comments

  1. Sivakumar says

    April 23, 2017 at 11:14 PM

    Very good information. Thanks sir, I need some more information magnetic coupling pump what are the applications are used and this main advantage of magnetic coupling pump. We are using magnetic coupling pump for HTM oil and some HTM oil pump with out Magnetic coupling pump also using.comparesion magnetic coupling pump failure is high.

    Reply
    • Fred Schenkelberg says

      April 24, 2017 at 8:00 AM

      Thanks for the comment. A good place to find information and benefit of magnetic coupling pumps is with a vendor or manufacturer of such devices. They can also take the time to understand your application. cheers, Fred

      Reply
  2. QAIS AL ABRI says

    May 14, 2023 at 12:27 AM

    thank for useful information
    any concern in reverse flow ?

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Article by
Mike Sondalini
in the
Plant Maintenance series.

Join Accendo

Receive information and updates about articles and many other resources offered by Accendo Reliability by becoming a member.

It’s free and only takes a minute.

Join Today

Recent Articles

  • Gremlins today
  • The Power of Vision in Leadership and Organizational Success
  • 3 Types of MTBF Stories
  • ALT: An in Depth Description
  • Project Email Economics

© 2025 FMS Reliability · Privacy Policy · Terms of Service · Cookies Policy